Precision Power for Demanding Applications
The Vector Series combines advanced IGBT technology with digital control to deliver high-efficiency, fast-response DC power. Designed for industrial and utility environments where reliability and precision are critical, Vector ensures stable output under dynamic conditions and integrates seamlessly with SCADA/BMS for smart monitoring
Modern infrastructure requires more than just reliability — it demands precision, intelligence, and resilience. The Vector Series addresses these needs with >90% efficiency, unity power factor, and robust protection. Whether powering substations, refineries, or defense systems, Vector guarantees uninterrupted auxiliary DC supply
>90% efficiency, near-unity PF, low harmonics.
Stable DC even during rapid load variations.
DSP-based control with ±1% voltage accuracy.
Protection from surges, overloads, and thermal stress.
Smaller footprint vs. thyristor chargers.
RS485/Ethernet/Modbus for SCADA/BMS.
Supports multi-mode charging and Li-ion integration
| Specification | Details |
|---|---|
| Input AC Supply | 415 V ±10%, 3PH / 3/4 Wire, 50–60Hz ±5% or 230 V ±10% |
| DC Output Voltages | 24V, 48V, 110V, 125V, 220V, 360V |
| DC Output Current | 5A – 3000A (other ratings on request) |
| Standards | IS 4540, IEC 146 |
| Certifications | ISO 9001, ISO 14001, ISO 45001, ZED certified |
| Supported Batteries | Lead Acid, VRLA, Ni-Cd, Li-Ion |
| Charging | Constant Current / Constant Voltage (CC–CV) |
| Cell Configuration | 24V: LA/VRLA (11–13 cells), Ni-Cd (19–21) |
| 48V: LA/VRLA (23–25), Ni-Cd (38–41) | |
| 110V: LA/VRLA (53–56), Ni-Cd (85–87) | |
| 125V: LA/VRLA (62), Ni-Cd (98–100) | |
| 220V: LA/VRLA (108–111), Ni-Cd (169–176) | |
| 360V: LA/VRLA (180), Ni-Cd (278–284) |
| Category | Details |
|---|---|
| Output | DC Voltmeter, DC Ammeter (optional) |
| Battery | DC Voltmeter, DC Ammeter (optional) |
| Input | AC Voltmeter, AC Ammeter (optional) |
| Display | LCD/Touchscreen for monitoring |
| Protection Feature | Details |
|---|---|
| Rectifier Module Protection | MCB safeguard for rectifier module |
| Soft Start | Prevents inrush currents during startup |
| Electronic Current Limit | Restricts current to safe operating levels |
| Phase Protection | Phase sequence reversal & phase failure protection |
| Category | Details |
|---|---|
| Annunciations |
|
| Relay Contacts | Potential free (optional) |
| Communication | RS485 (optional) |
| Specification | Details |
|---|---|
| Construction | Folded sheet MS, powder coated |
| Frame Thickness | 2 mm |
| Panels | 1.6 mm |
| Cable Entry | Bottom (top on request) |
| Panel Access | Front & rear (front-only optional) |
| Enclosure | IP20 / IP31 / IP42 (higher on request) |
| Cooling | Natural or forced air |
| Noise | 70 dBA (natural), 80 dBA (forced) |
| Installation | Indoor, floor-mounted, self-standing |
| Condition | Details |
|---|---|
| Temperature | 0°C to +50°C |
| Humidity | ≤95% RH (non-condensing) |
| Altitude | ≤1000m above MSL |
More than just power backup — we deliver engineering reliability, tailored solutions, and unmatched service that keeps your business running 24/7.
Chhabi Electricals Pvt. Ltd. E-66, MIDC Area, Ajanta Road, Jalgaon – 425003, Maharashtra, India
Lodha Supremus-1, Office No.609, 6th floor, Road No.22, Wagle Industrial Estate, Near- New Passport Office, Thane (W)-400604 (M.S.) India
Copyright © 2025 All Rights Reserved.