Intelligent Power for the Digital Age
When real-time insights and smart control matter, the Agile Alpha Series acts as your 24/7 power guardian. More than just a charger, it optimizes performance, prevents failures, and keeps you in command with advanced monitoring and automation
The Agile Alpha Series brings digital intelligence to DC UPS charging. It combines precision power regulation with real-time monitoring, predictive diagnostics, and adaptive charging modes. Designed for mission-critical applications, it ensures consistent power quality while extending battery life and reducing downtime
DSP/microcontroller closed-loop control ensures ±1% regulation accuracy.
7-inch LCD/touchscreen for live data, alarms, and mode visualization.
Monitors 25+ parameters (ripple, harmonics, battery impedance).
Auto-switches between Float/Boost/Equalize with temperature compensation.
Supports Modbus RS-485, RS-232, TCP/IP, Profibus; remote read/write facility
| Specification | Details |
|---|---|
| Input AC Supply | 415 V AC ±10%, 3PH, 3/4 Wire, 50Hz or 60Hz ±5% or 230V AC ±10% |
| DC Output Voltages | 24V, 48V, 110V, 125V, 220V, 360V |
| DC Output Current Range | 5A – 3000A (other ratings on request) |
| Applicable Standards | IS 4540, IEC 146 (as applicable) |
| Quality Standard | ISO 9001, ISO 14001, ISO 45001 & ZED (Zero Defects Zero Effects) certified |
| Supported Battery Types | Lead Acid, VRLA (Valve Regulated Lead Acid), Nickel Cadmium, Li-Ion |
| Charging Characteristics | Constant Current, Constant Voltage (CC-CV) |
| Cell Configuration | 24V: LA/VRLA (11–13 cells), NiCd (19–21 cells) |
| 48V: LA/VRLA (23–25), NiCd (38–41) | |
| 110V: LA/VRLA (53–56), NiCd (85–87) | |
| 125V: LA/VRLA (62), NiCd (98–100) | |
| 220V: LA/VRLA (108–111), NiCd (169–176) | |
| 360V: LA/VRLA (180), NiCd (278–284) | |
| DC Output Voltage | Float Mode: LA 2.15–2.2 VPC, VRLA 2.15–2.25 VPC, NiCd 1.40–1.42 VPC |
| Boost Mode: LA 2.65–2.75 VPC, VRLA 2.3–2.35 VPC, NiCd 1.65–1.7 VPC | |
| Voltage Regulation | ±1% (0–100% load, float mode) |
| Current Variation | Adjustable 10%–100% (boost mode) |
| Current Limit | 105% of rated current (float mode) |
| DC Current Regulation | ±2% (boost mode) |
| Magnetics | Isolation transformer / Filter choke |
| Insulation Class | F, Temperature rise: 90°C (for magnetics) |
| High Voltage Withstand | 2.5 kV for 1 min |
| Rectifier Type | Fully controlled bridge (6/12/24 pulse thyristor) |
| Output Ripple | ≤1% RMS / 2% RMS / 3% RMS or Peak to Peak (without battery connected) |
| Efficiency | ≥80% at full load (110V, 220V, 360V models) |
| ≥70% at full load (24V, 48V models) |
| Category | Details |
|---|---|
| Output | DC Voltmeter, DC Ammeter |
| Battery | DC Voltmeter, DC Ammeter |
| Input | AC Voltmeter, AC Ammeter (optional) |
| Display | Through LCD / Touchscreen |
| Protection Feature | Details |
|---|---|
| Thyristor Protection Fuse | Provides safety for thyristors against faults |
| Soft Start | Prevents inrush currents during startup |
| Electronic Current Limit | Restricts current to safe operating levels |
| Phase Protection | Phase sequence reversal & phase failure protection |
| Category | Details |
|---|---|
| Alarms / Annunciations |
|
| Status Indications | Relay Contacts: Potential free (optional) |
| Communication | RS485 (optional) |
| Specification | Details |
|---|---|
| Construction | Folded sheet MS, powder coated (Paint Shade – Customizable) |
| Sheet Thickness | Frame (Load bearing members) – 2 mm, Panels (Non-load bearing members) – 1.6 mm |
| Cable Entry | Bottom (top on request) |
| Panel Access | Front & rear; Only front on request |
| Terminal Arrangement | Back side |
| Enclosure Protection | IP20 / IP31 / IP42 (others i.e. IP5x on request) |
| Cooling | Natural air cooling / Forced air cooling |
| Noise Level | 70 dBA (natural) / 80 dBA (forced cooling) |
| Installation | Indoor, floor mounting, self-standing |
| Condition | Details |
|---|---|
| Temperature | 0°C to +50°C |
| Humidity | ≤95% RH (non-condensing) |
| Altitude | ≤1000m above MSL |
More than just power backup — we deliver engineering reliability, tailored solutions, and unmatched service that keeps your business running 24/7.
Chhabi Electricals Pvt. Ltd. E-66, MIDC Area, Ajanta Road, Jalgaon – 425003, Maharashtra, India
Lodha Supremus-1, Office No.609, 6th floor, Road No.22, Wagle Industrial Estate, Near- New Passport Office, Thane (W)-400604 (M.S.) India
Copyright © 2025 All Rights Reserved.